banner

Air Cooled Glycol Chiller System With -5C Outlet

Delivery term:The date of payment from buyers deliver within days
  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Guangdong

  • Validity to:

    Long-term effective

  • Last update:

    2017-10-28 13:09

  • Browse the number:

    453

Send an inquiries
Company Profile
Shenzhen Anyda Refrigeration Equipment Co.Ltd
By certification [File Integrity]
Contact:

anyida(Mr.)  

Email:

Telephone:

Phone:

Area:

Guangdong

Address:

NO.6-2 west of egongling industrial district,pingdi street

Website: http://www.anyda-chiller.com/ http://anyida.ballsoffluff.com/
Product details

Air Cooled Glycol Chiller System With -5degrees Outlet

We supply air cooled glycol chiller system with -5C outlet. There are varies minus temp outlet and there will be a one suitable for you.

Air Cooled Glycol Chiller System With -5degrees Outlet


1.Introduction of Air Cooled Glycol Chiller System With -5degrees Outlet

This air cooled glycol chiller system with -5C outlet designed of case type, compact structure, scientific design appearance, full paint rust and corrosion.Cooling medium can be ethylene glycol and salt water, the use of special materials and processes, to eliminate the phenomenon of corrosion and oxidation of the evaporator, the use of equipment to extend the cycle.


2.Structure of Air Cooled Glycol Chiller System With -5degrees Outlet



3.Parameters of 5ton industrial plastic air cooled water chiller system

Name

Glycol Chiller

Model

AYD-05A-LT

Cooling Capacity (kw/h)

8.55

Cold glycol  Flow(m3/h)

2.5

Air Volume( m3/h)

5600

Refrigerant

R404A/R407C

Temp Control Outlet(℃)

-5

Compressor Input Power(KW)

3.75

The water pipe size (G")

1"

Power Supply

3N/380V/50HZ

Dimension(L×W×H)mm

1165*680*1540

Weight(KG)

270

Disposition:
1.Compressor:Sanyo/Copeland;
2.Punp brand electronic board of micro computer
3.LG Exchange the contactor, LG heat relay,Carlo Phase;

Protective Device:                    
1.Phase protector
2.Fan overload protector
3.High/low voltage protector
4.Water level protector
5.Anti-freeze protector
Remarks:The cooling capacity of the model is calculated according to condenser temperature 45℃, evaporator temperature  -10℃


4.Packaging & Shipping,Service  

 Packaging:

 Wooden case or simple package by a container.

 Delivery time:

 Standard chiller model lead time: 15-20 days

 Customized chiller lead time: 25 - 40 days

 Shipping:

 By sea

Our service:

1. Strong R & D team for chiller design and development;

 2. Customized product is welcome;

 3. Skilled workers and advanced manufacturing experience;

 4. Quick response and satisfaction to customers on each project;

 5. We adhere to philosophy of  “people orientation, customer first” always;

 6. We provide high quality, competitive price, 1year guarantee and technical support forever.


5.Company Information    
Shen Zhen Anyda Refrigeration Equipment Co., Ltd. is a high-tech private enterprise which was established in 2013,with the registered capital of 5 million yuan, covers an area of 8900 square meters, Anyda gradually grow up step by step.
Anyda is specialized in the research, production and trading of industrial refrigeration technology and facilities. We have gradually produced Industrial Chiller,Water Chiller,Air Cooler,Oil Chiller,Low Temperature Chillers,Hot Water Chiller, Heat Pumps and Central Air Conditioner which are widely applied to  plastic & rubber machinery, daily-use chemical, textile, general machinery, laser machinery, LCD and PCB industry, electroplating, equipments of laboratory, food, pharmacy, etc .  
Now we own almost one hundred staff and about five of them are engineers with 15years of chiller R & D and production management manufacturing experience which provide the best technical support to our customer.
We gained the certification of ISO9001:2008 and CE international quality management systems. We have exported to Russia,Uzbekistan,Kazakhstan,Saudi Arabia,Africa,Indonesia,Malaysia,Romania,Bulgaria,Australia,Palestine,SriLanka,Mexico,Amercia,Lebanon ,Lithuania and so on,which covered about USD2millions.We are looking forward to your suggestion, and are confident of becoming your choice!


6.FAQ
1.How water chiller work?
Chiller has two circulation,one is process water circulation,the other is refrigerant gas circulation.Heat picked up from the process.Heat transfers to refrigerant circulation.Heat is remove to air or water.

2.How to calculate chiller load?
Cooling Capacity(kw)= Flow Rate(m3/h)*Temp Change(T1-t2)/0.86
Heat Load= C(specific heat)* M(quality output per hour )*Temp Change(T1-T2)

3.Types of chiller?
Air Cooled Chiller and Water Cooled Chiller.Water cooled chiller needs a separated cooling tower and has a higher efficiency,but less easier than air cooled.

4.Chiller capacity unit conversion?
1 kcal/h = 1.163W,1 W = 0.8598 kcal/h;
1 Btu/h = 0.2931W,1 W = 3.412 Btu/h;
1 USRT  = 3.517 kW,1 kW = 0.28434 USRT;  
1 kcal/h = 3.968 Btu/h,1 Btu/h = 0.252 kcal/h;
1 USRT = 3024 kcal/h,10000 kcal/h = 3.3069 USRT;

5.Chiller maintenance?

Step 1: Keep Tubes Clean

Step 2: Ensure a Leak-free Unit

Step 3: Sustain Proper Water Treatment(prevent scale, corrosion)

Step 4: Analyze Oil and Refrigerant

ANYDA is well acknowledged as one of the leading manufacturers of air cooled glycol chiller system with -5c outlet in China. All of the products for sale are made in our professional plant. Should you're interested in it, please be free to get the high-tech equipment with competitive price from us.